FLAM Issue Tracker - FL5
View Issue Details
0000924FL54. Element, Byte, Record or other APIpublic2018-07-27 09:532018-08-23 18:14
Falk Reichbott 
Ulrich Schwab 
normalminoralways
resolvedfixed 
GeneralGeneralGeneral
5.1.17 
5.1.185.1.18 
0000924: The packaging for MF-EDZ platforms must contain each open and singelton Funktion as DLL/SO of FCRRECMF
Currently the packaging provides only the FCROPN.dll/so, but this must not the first call in a COBOL program. Each singelton function (FCRINF/VSN/ABO/...) and each open function (FCROPN/OPNL(OPNV/...) needs to provided as DLL.
No tags attached.
Issue History
2018-07-27 09:53Falk ReichbottNew Issue
2018-07-27 09:53Falk ReichbottStatusnew => assigned
2018-07-27 09:53Falk ReichbottAssigned To => Ulrich Schwab
2018-07-30 18:13Falk ReichbottSummaryThe packaging for MF-EDZ platforms must contain each open and sinelton Funktion as DLL/SO of FCRRECMF => The packaging for MF-EDZ platforms must contain each open and singelton Funktion as DLL/SO of FCRRECMF
2018-08-23 18:14Falk ReichbottNote Added: 0001182
2018-08-23 18:14Falk ReichbottStatusassigned => resolved
2018-08-23 18:14Falk ReichbottFixed in Version => 5.1.18
2018-08-23 18:14Falk ReichbottResolutionopen => fixed

Notes
(0001182)
Falk Reichbott   
2018-08-23 18:14   
Now only the original DLL/SO is part of the package and there are sample scripts to hard link or copy the DLL/SO under the required names. The detailed procedure for MF-EDZ installation can find in the install.txt for Windows and Linux.