FLAM Issue Tracker - FL5 |
View Issue Details |
|
ID | Project | Category | View Status | Date Submitted | Last Update |
0000924 | FL5 | 4. Element, Byte, Record or other API | public | 2018-07-27 09:53 | 2018-08-23 18:14 |
|
Reporter | Falk Reichbott | |
Assigned To | Ulrich Schwab | |
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | |
Platform | General | OS | General | OS Version | General |
Product Version | 5.1.17 | |
Target Version | 5.1.18 | Fixed in Version | 5.1.18 | |
|
Summary | 0000924: The packaging for MF-EDZ platforms must contain each open and singelton Funktion as DLL/SO of FCRRECMF |
Description | Currently the packaging provides only the FCROPN.dll/so, but this must not the first call in a COBOL program. Each singelton function (FCRINF/VSN/ABO/...) and each open function (FCROPN/OPNL(OPNV/...) needs to provided as DLL. |
Steps To Reproduce | |
Additional Information | |
Tags | No tags attached. |
Relationships | |
Attached Files | |
|
Issue History |
Date Modified | Username | Field | Change |
2018-07-27 09:53 | Falk Reichbott | New Issue | |
2018-07-27 09:53 | Falk Reichbott | Status | new => assigned |
2018-07-27 09:53 | Falk Reichbott | Assigned To | => Ulrich Schwab |
2018-07-30 18:13 | Falk Reichbott | Summary | The packaging for MF-EDZ platforms must contain each open and sinelton Funktion as DLL/SO of FCRRECMF => The packaging for MF-EDZ platforms must contain each open and singelton Funktion as DLL/SO of FCRRECMF |
2018-08-23 18:14 | Falk Reichbott | Note Added: 0001182 | |
2018-08-23 18:14 | Falk Reichbott | Status | assigned => resolved |
2018-08-23 18:14 | Falk Reichbott | Fixed in Version | => 5.1.18 |
2018-08-23 18:14 | Falk Reichbott | Resolution | open => fixed |