Reporter | Falk Reichbott | ||||||||
Assigned To | Falk Reichbott | ||||||||
Priority | normal | Severity | feature | Reproducibility | N/A | ||||
Status | resolved | Resolution | not fixable | ||||||
Platform | System z | OS | z/OS | OS Version | V2R20 | ||||
Product Version | 5.1.15 | ||||||||
Target Version | 5.1.16 | Fixed in Version | 5.1.16 | ||||||
Summary | 0000883: Support of large records in VS/VBS datasets on z/OS | ||||||||
Description | Currently the record length of variable length host datasets can not exceed the LRECL-4. Means VS/VBS works for block sizes smaller then LRECL, for a first record segment at the end of the Block and a last segment at beginning of the next block, but not if total record length (first, n*middile, last) exceeds the defined logical record length. To support large records, the check of the record length for VS/VBS must be disabled and the record buffer must be increased. The size of the record buffer must be choosable. For this a multiple of the record length can be defined. A good default will be 16, if no value given. Means by default a VS/VBS file can hold records 16 time largner then LRECL-4. For example a SMF-Dump can hold up to 512k long records. If more required the user can increase the faktor. A faktor of 1 result in the old behavior. | ||||||||
Tags | No tags attached. | ||||||||
Attached Files | |||||||||
Notes | |
(0001109) Falk Reichbott (administrator) 2017-07-05 14:40 |
With version 5.1.16 of FLAM large records up to 256kib are supported if VBS or VS used. The implemented rule supports fix 8*(LRECL-4) if a VBS or VS data set is used. |
(0001110) Falk Reichbott (administrator) 2017-07-05 14:47 |
The dynamisation of records length for ANSI extended logical records and VS/VBS is still open and will be fixed in one of the next revisions. |
(0001111) Falk Reichbott (administrator) 2017-07-10 09:46 |
A large record support is currently not supported with LE access methods. A own implemenmtation over BSAM lcoate would be possible but realy expensive. Based on that we have only extent the VS/VBS support to exceed the LRECL up to 64kB, but the limit of the LE is 32k. Means no longer records can occur. |
Issue History | |||
Date Modified | Username | Field | Change |
2017-07-05 09:04 | Falk Reichbott | New Issue | |
2017-07-05 09:04 | Falk Reichbott | Status | new => assigned |
2017-07-05 09:04 | Falk Reichbott | Assigned To | => Falk Reichbott |
2017-07-05 14:40 | Falk Reichbott | Note Added: 0001109 | |
2017-07-05 14:47 | Falk Reichbott | Note Added: 0001110 | |
2017-07-10 09:46 | Falk Reichbott | Note Added: 0001111 | |
2017-07-10 09:46 | Falk Reichbott | Status | assigned => resolved |
2017-07-10 09:46 | Falk Reichbott | Fixed in Version | => 5.1.16 |
2017-07-10 09:46 | Falk Reichbott | Resolution | open => fixed |
2017-07-10 09:47 | Falk Reichbott | Resolution | fixed => not fixable |