FLAM® Issue Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000826FL51.2 FLCCpublic2016-10-11 10:402016-10-11 10:49
ReporterFalk Reichbott 
Assigned ToRolf-Dieter Euler 
PrioritynormalSeverityminorReproducibilityalways
StatusresolvedResolutionfixed 
PlatformSystem zOSz/OSOS VersionV2R20
Product Version5.1.13 
Target Version5.1.13Fixed in Version5.1.13 
Summary0000826: Prevent RACF and LOGR messages if no log stream for usage logging defined
DescriptionCurrently FLAM try to connect to log stream FLAM.USAGE if no system variable (&FLOGQLx) defined. This results in a lot of messages from RACF and LOGR is this log stream not defined or the corresponding RACF settings not done.

The customers request to prevent these messages.
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
(0001028)
Falk Reichbott (administrator)
2016-10-11 10:45
edited on: 2016-10-11 10:49

The connect to a log stream will now (>5.1.13-15352) only be done if the corresponding system variables defined.

e.g. SYS1.PARMLIB(IEASYM00)
   SYMDEF(&FLOGQL1='FLAM')
   SYMDEF(&FLOGQL2='USAGE')

Additonal the SRB time is now called offload time, which is more platform indepentend.


- Issue History
Date Modified Username Field Change
2016-10-11 10:40 Falk Reichbott New Issue
2016-10-11 10:40 Falk Reichbott Status new => assigned
2016-10-11 10:40 Falk Reichbott Assigned To => Rolf-Dieter Euler
2016-10-11 10:45 Falk Reichbott Note Added: 0001028
2016-10-11 10:45 Falk Reichbott Status assigned => resolved
2016-10-11 10:45 Falk Reichbott Fixed in Version => 5.1.13
2016-10-11 10:45 Falk Reichbott Resolution open => fixed
2016-10-11 10:49 Falk Reichbott Note Edited: 0001028 View Revisions


Copyright © 2000 - 2024 MantisBT Team